Multiprocessing tank is used for producing starter.
Click the picture to zoom it (in the new window) !
Multiprocessing tanks M100 M160 M300
type
dimensions
engine
power
zactive energy consumption in 1
cycle
weight
occupied surface
a
b
c
d1
d2
e
f
G
heating steam
cooling waters
l
mm
kW
kg
m3
kg
m2
M100
100
1070
1415
1005
560
765
540
580
400
0,4
20
1,2
165
0,9
M160
160
1070
1660
1250
560
765
540
580
400
0,4
30
1,8
205
0,9
M300
300
1300
1550
1060
800
960
410
410
220
0,4
70
4,0
288
1,3
230.2
Multiprocessing tanks
M1200
M1500
Multiprocessing tank is used for running technological processes which
require mixing and heating and cooling down the product. Tank's
thermal insulation allows to process the contents in isothermal alike
conditions.
Technical data:
capacity - 1.200/1.500 l;
engine power - 1,5/1,5 kW;
stirrer rotating - 15/15 rotations/min;
outer diameter - 1.400/1.400 mm;
weight - 600/750 kg;
height - 2.130/2.450 mm.
Click the picture to zoom it (in the new window) !
Multiprocessing tanks M1200 M1500
230.3
Multiprocessing tanks
KDP-4
KDP-8
KDP-12
Multiprocessing tank for long lasting pasteurization is used for
running technological processes which require processing fluids in
isothermal alike conditions.
Type
capacity
[l]
dimensions
[mm]
weight
[kg]
a
b
c
d1
d2
e
KDP-4
400
1800
1376
726
1000
1130
520
460
KDP-8
800
1940
1604
1280
1240
1374
650
500
KDP-12
1200
1940
1936
1610
1240
1374
650
660
Click the picture to zoom it (in the new window) !
Multiprocessing tank DP-4 KDP-8 KDP-12
230.4
Multiprocessing tank
M1000/2
Multiprocessing tank is used for running technological processes which
require mixing and heating and cooling down the product. Tank's
thermal insulation allows to process the contents in isothermal alike
conditions.
Technical data:
capacity - 1.000 l;
engine power - 0,37 kW;
stirrer rotating - 320 rotations/min;
outer diameter - 1.400 mm;
weight - 550 kg;
height - 2.020 mm;
heating milk time from temperature 10oC to 95oC
- 50 min.;
cooling down from temperature 95oC to 20oC
- 35 min.;
cooling down from temperature 80oC to 6-8oC
- 15 min.;
ice water demand with temperature 3oC for cooling -
10.000 l/hr;
saturated vapour demand - 250 kg/hr at pressure 0,03 atm.
Click the picture to zoom it (in the new window) !